p. 205-212, PERGAMON-ELSEVIER SCIENCE LTD, THE BOULEVARD, LANGFORD LANE, KIDLINGTON, OXFORD OX5 1GB, 2010. : Ceiling radiant cooling: Comparison of ARMAX and subspace identification modelling methods . BUILDING AND ENVIRONMENT, vol. 2010,
Abstrakt
The building of the Faculty of Mechanical Engineering, Czech Technical University in Prague - Dejvice, has been heated by a ceiling radiant heating system ("Crittall" system) since 1961. One building block has been equipped by means which enable the use of the pipes of the radiant heating system for ceiling radiant cooling. As optimization of this system is desired, the first step to be performed is the identification. Because of a complicated physical description of the entire system, and a set of measured data which is large enough to perform statistical identification, a decision was made to identify the system by ARMAX model identification and subspace identification methods. The resulting identified model shows a standard deviation of 0.2-0.3 degrees C on the verification data. The model identified by the subspace methods, enhanced by a Kalman filter, shows a standard deviation of 0.063 degrees C for output tracking. Such a model is ready to be used in modern multidimensional controllers, such as model-based predictive controllers (MPC).
Abstrakt v češtině
Budova Fakulty Strojní, ČVUT v Praze Dejvicích je od roku 1961 vytápěna podlahovým systémem označovaným jako Crittallové topení. Jeden blok budovy byl vybaven tak, aby mohl být Crittall využit i pro chlazení. Snahou je zajištění optimálního provozu a tak bylo přistoupeno k identifikaci modelu budovy. Vzhledem k složité konstrukci budovy byla zvolena identifikace modelu z historických dat. Bylo nutné rozhodnout jestli budou využity techniky subspace identfikikace a nebo jestli bude model identifikován v podobě ARMAX modelu. Model identifikovaný pomocí subspace metod vykazoval odchylku pouze 0.2-0.3 stupňů C, kKdyž byl doplněn Kalmanovým filtrem, tak pouze 0.063 stupňů C. Takový model je využitelný i v prediktivních regulátorech.
Detail publikace
Název: | Ceiling radiant cooling: Comparison of ARMAX and subspace identification modelling methods |
---|---|
Autor: | Ferkl Lukáš ; Široký Jan |
Název - česky: | Stropní chlazení: Porovníní ARMAX a subspace identifikace |
Jazyk publikace: | anglicky |
Rok vydání: | 2010 |
Typ publikace: | Článek z časopisu |
Název časopisu / knihy: | BUILDING AND ENVIRONMENT |
Číslo vydání: | 2010 |
Strana: | 205 - 212 |
ISSN: | 0360-1323 |
Nakladatel: | PERGAMON-ELSEVIER SCIENCE LTD |
Místo vydání: | THE BOULEVARD, LANGFORD LANE, KIDLINGTON, OXFORD OX5 1GB |
Klíčová slova
Cooling, Building management systems, System identification, Subspace methods, ARMAX, Modelling
Klíčová slova v češtině
Chlazení, Systémy správy budov, Identifikace systémů, Subspace metody, ARMAX, Modelování
BibTeX
@ARTICLE{FerklLukas_2010_Ceilingradiant, author = {Ferkl Luk\'{a}\v{s} and \v{S}irok\'{y} Jan}, title = {Ceiling radiant cooling: Comparison of ARMAX and subspace identification modelling methods}, year = {2010}, publisher = {PERGAMON-ELSEVIER SCIENCE LTD}, journal = {BUILDING AND ENVIRONMENT}, address = {THE BOULEVARD, LANGFORD LANE, KIDLINGTON, OXFORD OX5 1GB}, volume = {2010}, pages = {205-212}, ISSN = {0360-1323}, note = {vr\'{a}ceno na \v{z}\'{a}dost KKY, ve WoS ani u \v{c}l\'{a}nku nen\'{i} autor ve vazb\v{e} na Z\v{C}U.}, url = {http://www.kky.zcu.cz/en/publications/FerklLukas_2010_Ceilingradiant}, }